Goal of the session: a common understanding within the client's R&D team of what ESD and ATEX properties mean for the design and construction of conveyor belts – and how a belt can be proven safe.
Agenda · 3 hours

Five modules, from the atmosphere to the proof

A question to start with

Is this belt allowed in Zone 1?

0 Ω1000 V · 60 s · 23 °C / 50 %rh · strip electrodes

A light conveyor belt has a surface resistance of about 1011 Ω on its conveying side – more than a thousand times above the usual "dissipative belt" limit.

Keep your answer in mind – we will come back to it in Module 5 with real laboratory results.
01
Module 1

ATEX basics – when can a belt ignite an atmosphere?

ATEX basics

Five conditions must meet

FuelOxygenIgnition sourceMixingConfinement

Fire triangle

Fuel, oxygen and an effective ignition source together produce a fire.

+ Mixing and confinement

When the fuel is finely mixed with air within its explosion limits and the volume is confined, the combustion propagates so quickly that pressure builds up: an explosion.

Explosion protection = remove one condition

Primary: avoid the explosive atmosphere. Secondary: avoid effective ignition sources – this is where the electrostatic properties of a conveyor belt matter.

ATEX basics

Three kinds of explosive atmosphere

Flammable gases

Hydrogen, methane, propane, ethylene… Explosive between the lower and upper explosion limits (LEL–UEL), e.g. methane ≈ 4.4–17 vol%.

Vapours of flammable liquids

Solvents, cleaning agents, adhesives. Relevant as soon as the liquid temperature reaches its flash point. Wet or freshly coated products on a belt release vapours.

Combustible dusts

Wood, flour, sugar, plastics, metals… Explosive as a cloud, typically from a few tens of g/m³. A 1 mm dust layer, once whirled up, can fill a 5 m high room with an explosive cloud.

ATEX basics

Zones: how often is the atmosphere there?

Gases & vapours · dusts
A belt conveyor is typically in Zone 21 or 22 (dust transfer points) or Zone 1 or 2 (solvent-wet products, coating lines).
The zone decides which ignition sources must be excluded and how reliably – including electrostatic discharges.
ATEX basics

How easily can the atmosphere be ignited?

Hydrogen · IICMIE 0.019 mJ – most sensitive group
Ethylene · IIBMIE ≈ 0.07 mJ
Propane · IIAMIE ≈ 0.25 mJ – most solvents are IIA
Combustible duststypically ≈ 1 mJ to above 1 J (band)
Tower height = logarithm of the MIE, from 0.01 mJ to 10 J (grid lines = decades).

Gas groups IIA · IIB · IIC

Classified by ignitability: IIC (hydrogen, acetylene) is the most sensitive, IIA (propane, most solvents) the least. Many limits for belts depend on the group.

Dust groups IIIA · IIIB · IIIC

IIIA combustible flyings, IIIB non-conductive dust, IIIC conductive dust. For dusts the MIE of the specific product is decisive (≥ 10 mJ or < 10 mJ in the belt tables).

ATEX basics · EN 1127-1 / ISO 80079-36

13 ignition sources – four of them live on a conveyor

01

Hot surfaces

Blocked roller, belt slipping on the drive drum, bearings
02

Flames and hot gases

03

Mechanical sparks

Metal parts rubbing or impacting, tramp metal
04

Electrical equipment

Drive motor, sensors, switches
05

Stray currents, cathodic protection

06

Static electricity

Belt–drum separation, product, isolated parts
07

Lightning

08

Radio-frequency waves

09

Optical radiation

10

Ionising radiation

11

Ultrasonics

12

Adiabatic compression

13

Exothermic reactions

Static electricity is the ignition source a belt manufacturer can influence most directly – through the belt's materials and construction.
ATEX basics · regulatory framework

Three players, one chain of information

Belt manufacturer

Belt properties

  • Material and construction of the belt
  • Electrostatic properties: resistances, chargeability, test reports
  • Conditions of use: grounded conductive pulleys, speed, splicing, cleaning
Conveyor manufacturer

Equipment for Ex areas

  • Directive 2014/34/EU (CH: VGSEB)
  • Ignition hazard assessment, ISO 80079-36/-37
  • Selects a belt that matches the category, group and speed
Operator

Workplace safety

  • Directive 1999/92/EC (CH: Suva rules, e.g. leaflet 2153)
  • Zoning, explosion protection document
  • Inspection and maintenance: earthing, wear, cleaning
A belt is not "ATEX certified" on its own: its electrostatic data feed the ignition hazard assessment of the conveyor – and its conditions of use must reach the operator.
02
Module 2

Electrostatics basics – from contact to discharge

Electrostatics basics

Charge is created by contact and separation

VOLTAGE U0 V
1 · Contact: electrons cross the interface

Contact

At the interface, electrons move from one material to the other – even without friction. Friction only multiplies the contact points.

Separation

When the surfaces part, the charges stay behind. The capacitance between them collapses, so the voltage rises to kilovolts.

U=QC
Qcharge (constant)Ccapacitance (falls with distance)
On a conveyor this happens continuously along the line where the belt leaves the drive drum – the belt carries the charge away.
Electrostatics basics

Which material gets which sign?

+ POSITIVE

Click a belt material, then a contact partner.

The series is indicative: additives, pigments, surface finish, contamination and humidity can change the ranking. The larger the distance, the stronger the charging – but even identical materials charge each other.
Electrostatics basics

Accumulation or dissipation?

Volume resistivity ρ
conductivedissipativeinsulating
τ=ε0·εr·ρ
τrelaxation timeε08.85·10⁻¹² F/mεr≈ 3 (polymers)ρvolume resistivity
Relaxation time
–
–
Charge only becomes dangerous if it is generated faster than it can relax to earth. A belt reaches the next grounded roller within fractions of a second.
Electrostatics basics

Three resistances – three different questions

Surface resistance Rs

Can charge spread across the surface? Surface resistivity ρs = 10 · Rs for strip electrodes. Ring electrodes (ISO 284) give values 4× higher than strips.

Volume resistance Rv

Can charge cross the belt to the pulley side? ρv = Rv · A / h. Decisive for layered belts with an insulating cover.

Leakage resistance to earth

Does the charge really reach earth? Criterion U = I · R with U ≤ 100 V: 1 MΩ is always sufficient, metal parts < 10 Ω (IEC TS 60079-32-1, cl. 13).

Electrostatics basics

Four discharge types around a conveyor

Spark

Up to joules · E = ½ C U²

Between two conductors, one of them isolated and charged. All the stored energy is released in one shot.

On a conveyor: ungrounded rollers or drums, metal belt fasteners, parts of the frame, people.

Brush

Up to ≈ 3–4 mJ

From a charged insulating surface to a grounded, rounded conductor approaching it.

On a conveyor: highly charged belt surface or insulating product near a grounded part, a probe or a hand.

Propagating brush

Up to several joules

Thin insulating layer, highly charged on both faces (double layer), e.g. on a conductive backing. Very powerful.

On a conveyor: thin insulating belt or coating repeatedly charged over a metal slider bed.

Corona

Very low energy

Continuous, weak glow at sharp grounded points in a strong field. Normally not incendive.

On a conveyor: conductive threads in the belt fabric – some belts dissipate their charge by corona.
Electrostatics basics

Which discharge ignites what?

DischargeEnergyGases & vapours
IIA · IIB · IIC
Dusts
clouds without gas or vapour
SparkµJ to J – depends on C and UYesYes
Brushup to ≈ 3–4 mJYesNo
Propagating brushup to several JYesYes
Coronavery lowNormally noNo
Hybrid mixtures (dust + solvent vapour) behave like the vapour: brush discharges can ignite them.
Instead of energy, the incendivity of sparks and brushes is assessed by the transferred charge Q in nC – the basis of the belt tests in Module 5.
?
Quiz

Your turn

A highly charged belt produces brush discharges in a cloud of wood dust (no solvent). Can the dust be ignited?
Click the answer of the group, then → to reveal.
03
Module 3

Conveyor belts in operation – where the risk really comes from

Conveyor belts in operation

Anatomy of a belt conveyor

Main parts

  • Drive drum (head pulley) with motor and gearbox
  • Tail pulley
  • Return rollers under the return run
  • Slider bed (steel) under the carrying run
  • Belt: conveying side up, pulley side on the drums
  • Frame, legs, bearings – the earthing path (green-yellow)
  • Hopper at the discharge

Inside a light conveyor belt

Four layers, glued and calendered together. Its electrostatic behaviour depends on the materials, the additives – and on how the layers are connected.

Taken apart

  • Cover · PVC / PU / TPU, conveying side (top)
  • Tension member · PET / PA fabric
  • Conductive yarns or layer (optional)
  • Pulley side · fabric or impregnated (bottom)
Conveyor belts in operation

Where is charge generated?

1 · Belt leaving the drive drum

The main source: continuous separation under tension. Charge rises with speed, tension and contact width.

2 · Sliding on the slider bed

Friction of the pulley side on steel – a second separation surface.

3 · Product on and off the belt

The product leaves charged. A dissipative belt cannot discharge an insulating product.

4 · Where the charge goes

Isolated rollers, scrapers or fasteners collect it – until a spark.

Interactive · 3D conveyor explorer

Walk around a running conveyor

Drag to rotate · wheel to zoom · click a numbered point

Belt type
Rollers & drums
Splice
Conveyed product
Atmosphere
Speed
Humidity
Assessment–
Transferred charge
    Qualitative training model. Charge values are scaled on the laboratory results of Module 5 and are illustrative – not an assessment.
    Conveyor belts in operation

    Grounding: the decisive barrier

    Roller potential
    0 V
    Spark energy
    –
    Isolated roller, C ≈ 30 pF, charged by the belt at 0.1 µA: U = I·t / C until the gap breaks down (≈ 10 kV) – then E = ½ C U² ≈ 1.5 mJ, six times the MIE of propane.

    Grounded

    With R < 1 MΩ even 100 µA give less than 100 V: no hazardous potential. Metal parts: aim for < 10 Ω.

    Isolated

    Grease films in bearings, plastic bushings or painted joints isolate a roller. It charges up like a capacitor and discharges as a spark.

    Lab evidence (Module 5)

    Same belt, same roller: 192–241 nC with the roller ungrounded – 0–15 nC with the roller grounded.

    Conveyor belts in operation

    What drives the charge level?

    Relative charging tendency

    IEC TS 60079-32-1 (6.4): charge increases with velocity, tension and width of contact. Wax or dirt raise chargeability and resistance; below ≈ 30 %rh hygroscopic additives stop working.
    Conveyor belts in operation

    ESD and ATEX: two different questions

    ESD

    ProtectsElectronic components and assemblies against damage
    ThreatDischarges of a few volts to hundreds of volts – far below what ignites a gas
    Typical criteriaResistance to ground within a window (e.g. < 10⁹ Ω), low field and voltage near the product
    ReferencesIEC 61340-5-1 (ESD control) · ISO 21178 resistances and ISO 21179 field of a running light conveyor belt
    ≠

    ATEX

    ProtectsPeople and plant against explosions
    ThreatIncendive discharges: sparks, brushes, propagating brushes – kilovolts and nC
    Typical criteriaDissipative belt (< 300 MΩ ISO 284 / < 75 MΩ strips / < 1 GΩ through), grounded conductive pulleys, speed limits – or transferred charge below 60 / 25 / 10 nC
    ReferencesIEC TS 60079-32-1 · TRGS 727 · IEC 60079-32-2 · ISO 80079-36
    An ESD-compliant belt is not automatically suitable for an Ex area, and an Ex-suitable belt does not automatically meet an ESD specification: specify both separately.
    Conveyor belts in operation · for R&D

    Design levers for an Ex-suitable belt

    1Conductive cover

    Additives (carbon black, conductive fillers, permanent antistatics). Check colour constraints, ageing and humidity dependence.

    2Conductive yarns

    Conductive threads in the fabric dissipate by contact and corona – the belt then needs an expert test, not just a resistance value.

    3Through-conductivity

    No insulating adhesive or layer between conductive elements: through-resistance < 1 GΩ for layered belts.

    4Splices and repairs

    Must not increase the resistance or interrupt the conductive path. Metal fasteners: restricted by zone and speed.

    5Durability

    Abrasion, cleaning agents, wax and dirt change chargeability over the belt's life – test after ageing, not only new.

    6Instructions for use

    State the conditions under which the properties hold: conductive, grounded pulleys, speed range, climate, cleaning.

    ?
    Quiz

    Your turn

    A dissipative belt with metal fasteners runs at 3 m/s over grounded conductive pulleys in Zone 1, gas group IIB. Is this permitted?
    TRGS 727, table 2 · IEC TS 60079-32-1, table 5
    04
    Module 4

    What the standards require – IEC TS 60079-32-1 and TRGS 727

    IEC TS 60079-32-1, 6.4.2 · TRGS 727, 3.4 (2)

    When is a conveyor belt "dissipative"?

    a) ISO 284 / EN 14973
    < 300 MΩ both sides

    Surface resistance with the circular electrode and ring, at 23 °C and 50 %rh.

    b) Strip electrodes
    < 75 MΩ both sides

    Strip electrodes give values exactly 4 × lower than ISO 284 – hence 300 MΩ / 4.

    c) Layered belts
    < 1 GΩ through

    Resistance between the two opposite outer surfaces, at 23 °C and 50 %rh.

    Compare: a material counts as "dissipative" in general up to 100 GΩ surface resistance (IEC TS 60079-32-1, table 1). A belt must be about 1 000 × lower, because high-speed separation generates so much charge.
    IEC TS 60079-32-1, table 5 · TRGS 727, table 2

    Requirements by zone and belt speed

    Hazardous area≤ 0.5 m/s0.5 – 5 m/s5 – 30 m/s
    Zone 0Dissipative belt, conductive pulleys · no connectorsNot permittedNot permitted
    Zone 1 · IICDissipative belt, conductive pulleys · no connectorsNot permittedNot permitted
    Zone 1 · IIA, IIBDissipative belt, conductive pulleys · connectors permittedDissipative belt, conductive pulleys · connectors permittedDissipative belt, conductive pulleys · no connectors
    Zone 2No requirements beyond the general ones – unless experience shows incendive discharges
    Zone 20 · MIE < 10 mJDissipative belt, conductive pulleys · connectors permittedDissipative belt, conductive pulleys · connectors permittedNot permitted
    Zone 20 (MIE > 10 mJ) · Zone 21Dissipative belt, conductive pulleys · connectors permittedDissipative belt, conductive pulleys · connectors permittedDissipative belt, conductive pulleys · no connectors
    Zone 22No requirements beyond the general ones – unless experience shows incendive discharges
    Click a zone or a speed range to highlight it. Pulleys = drums and rollers, conductive and grounded. No experience above 30 m/s.Group I: as Zone 1 IIA/IIB
    IEC TS 60079-32-1, 6.4 · TRGS 727, 3.4

    Further requirements that concern the belt maker

    Only dissipative belts

    In hazardous areas only dissipative belts, running over conductive, grounded rollers and drums (TRGS 727, 3.4 (3)).

    Repairs

    Repairs of dissipative belts must not increase the resistance. Insulating adhesives must not interrupt the conductive path.

    Wax and dirt

    Layers of wax or dirt can increase both the chargeability and the resistance of the belt.

    Product is not discharged

    Conductive or dissipative belts cannot be expected to remove charge from an insulating conveyed product.

    Light conveyor belts

    For light belts (ISO 21183-1), ISO 21178 (resistances) and ISO 21179 (field of a running belt) exist and shall be used.

    Belts dissipating by corona

    Table 5 and the dissipative criteria do not apply: such belts have to be tested by experts under worst-case conditions.

    IEC TS 60079-32-1, 6.4.2

    The door for tested belts

    “

    Table 5 and the requirements in 6.4.2 do not apply to belts which dissipate charge by corona. Such belts have to be tested by experts e.g. by measuring their chargeability under worst case conditions.

    IEC TS 60079-32-1:2013, 6.4.2

    Why resistance alone fails

    A belt with conductive threads can show 1010–1011 Ω on its surface and still limit its charge by corona. The resistance criterion would wrongly exclude it.

    What "worst case" means

    Strong, continuous charging, low humidity, belt on a grounded roller – and the charge that a discharge can transfer. This is exactly what the dynamic method of Module 5 measures.

    IEC TS 60079-32-1, table 4 · ISO 80079-36

    The yardstick: maximum transferred charge

    GroupZone 0Zone 1Zone 2Zone 20Zone 21Zone 22
    IIA25 nC60 nC60 nC–––
    IIB10 nC25 nC25 nC–––
    IICno measurable discharge10 nC10 nC–––
    III–––60 nC*200 nC*200 nC*
    A sample is charged as highly as possible and a grounded sphere provokes a discharge; a coulombmeter measures the charge Q it transfers. Below the limit, the discharge is considered not incendive for that group and zone.
    * Group III values only for sparks from unearthed conductive or dissipative parts. Zone 1/21 limits ensure no incendive discharge in normal operation; Zone 0/20 limits are lower for abnormal situations.
    05
    Module 5

    Proving a belt safe – the dynamic charge-dissipation method

    Background

    A test approach built up with a belt manufacturer over several campaigns

    Phase 1

    First application

    Ignition hazards from electrostatic charging of conveyor belts in an industrial production line: resistances, charge transfer, ignition tests.

    Phase 2

    Follow-up campaign

    Same application, further belt types, same test logic – the basis of the method.

    Phase 3

    Conveyor belts

    Assessment of ignition hazards from electrostatic charging of conveyor belts, extended to new constructions.

    2023

    Belt type A

    Same programme – and the ignition test replaced by a new dynamic charge-dissipation test under continuous charging.

    Case study

    The tested belt: belt type A

    Belt sample hanging over a stainless-steel return roller Belt sample attached along its length
    BeltBelt type A
    Samples2 production lots
    Dimensions2000 × 400 × 1.7 mm
    Conveying sideblue
    Pulley sidewhite
    Main industryindustrial production lines
    Question to answer: does the belt dissipate its charge well enough to prevent incendive discharges – although its resistance is high?
    Case study

    Four tests, two climates

    Test 1

    Surface resistance

    Strip electrodes 100 mm / 10 mm
    1000 V, 60 s · both sides, warp and weft
    IEC 60079-32-2
    Climate 23 °C / 50 %rh
    > 75 MΩ
    Test 2

    Volume resistance

    Circular electrode, A = 0.002 m²
    1000 V, 60 s · conveying → pulley side
    EN 61340-2-3
    Climate 23 °C / 50 %rh
    > 1 GΩ
    Test 3

    Charge transfer

    Corona −70 kV, 10 cm, 30 s (10 s)
    Stainless roller Ø 55 mm, ≈ 350 cm² contact
    ISO 80079-36, annex D
    Roller grounded and ungrounded · 23 °C / 20 %rh
    0–15 nC vs 192–241 nC
    Test 4 · new

    Dynamic charge dissipation

    Corona kept on while measuring
    ≈ 10 µA (−30 kV, 10 cm) and ≈ 20 µA (−70 kV, 15 cm)
    14 positions per side
    Roller grounded · 23 °C / 20 %rh · ≥ 24 h conditioning
    ≤ 20 nC · ≤ 27 nC
    Case study · tests 1 and 2

    By its resistance, the belt is not "dissipative"

    Surface, conveying sideSurface, pulley sideVolumeDissipative zone (75 MΩ / 1 GΩ)Bars = geometric mean · grid = decades 10⁷ … 10¹³ Ω

    Surface: 1010 – 1012 Ω

    Both sides, both samples, both directions: well above the 75 MΩ belt criterion.

    Volume: 4·1010 – 5·1012 Ω

    Above the 1 GΩ through-resistance criterion for layered belts.

    The classical route via table 5 is closed. Only an expert test of the chargeability can show whether the belt is still safe.
    Case study · test 3 · ISO 80079-36, annex D

    Charge transfer: charge once, then discharge

    Transferred charge
    –nC
    Step through the test with →

    Set-up

    Belt hung over a stainless-steel tube Ø 55 mm (return roller), ≈ 350 cm² contact. Climate 23 °C / 20 %rh.

    1 · Charging

    Corona electrode at ≈ 10 cm, −70 kV for 30 s (10 s on the ungrounded set-up). Charging current ≈ 25 µA through the grounded roller.

    2 · Withdraw the electrode

    Moved far away while still energised – no back-spraying of charge.

    3 · Discharge to the sphere

    The coulombmeter's grounded sphere approaches and records the charge of one single discharge.

    The dynamic charge-dissipation method

    Why a static test is not enough

    Static test

    One charging, one discharge. It shows how much charge the surface can store – the charging has already stopped when you measure.

    Real operation

    Charge is generated continuously while it dissipates through the grounded rollers. What matters is the equilibrium charge under this flow.

    For a belt that dissipates by corona, the question is: can it evacuate a continuous charging current without building up a charge that gives incendive discharges?
    Charging currents range from 10 pA to 100 µA; in most operations they stay below 1 µA (IEC TS 60079-32-1, 13.2.2). The test uses 10 and 20 µA: a deliberately severe case.
    The dynamic charge-dissipation method

    Charge and measure – at the same time

    Charging current
    0µA
    Last discharge
    –nC

    Same set-up as test 3

    Belt on the grounded Ø 55 mm roller, pulley side in contact. An ammeter between roller and earth measures the current the belt evacuates.

    1 · Continuous charging

    The corona electrode stays on. In equilibrium, the charging current flows through the belt into the roller: ≈ 10 µA or ≈ 20 µA.

    2 · Measure while charging

    The coulombmeter sphere provokes a discharge at one position while the charging goes on – the worst case for the belt.

    3 · Recharge 30 s, next position

    14 positions on each side, both samples, both currents. Validity checked on a 10 × 10 cm PTFE reference plate (−50 to −144 nC).

    Case study · test 4 · results

    Where does the charge stay?

    Maximum
    –nC
    0 nC 1–25 nC > 25 nC
    Most positions show no measurable discharge. The highest values occur on the curved part close to the grounded roller (positions 12–14) and in the centre of the belt (position 5).
    Case study · test 4 · results

    All 112 discharges against the limits

    10 µA · sample 110 µA · sample 220 µA · sample 120 µA · sample 225 nC plane (IIB)60 nC plane (IIA)Left: conveying side C.1–C.14 · right: pulley side P.1–P.14
    10 µA: max 20 nC < 25 nC → meets the Zone 1 · IIB criterion
    20 µA: max 27 nC < 60 nC → meets the Zone 1 · IIA criterion
    Case study · interpretation

    What the results mean

    SideCharging currentTransferred charge
    Conveying side (blue)≈ 10 µA< 25 nC
    Conveying side (blue)≈ 20 µA< 60 nC
    Pulley side (white)≈ 10 µA< 25 nC
    Pulley side (white)≈ 20 µA< 60 nC
    Ungrounded rollerstatic, −70 kV> 60 nC (up to 241 nC)

    The belt dissipates

    Running over a grounded conductive roller, it keeps discharges below the gas-group limits even under severe continuous charging.

    Grounding is a condition

    Without grounded rollers, > 200 nC: above every limit, including dust sparks.

    Validity

    Results refer to the samples tested, 23 °C / 20 %rh, Ø 55 mm roller, 350 cm² contact, 10 / 20 µA. Test 4 is a non-accredited expert method.

    Back to the opening question

    Is a 1011 Ω belt allowed in Zone 1?

    A · not quite

    "Not dissipative, so excluded"

    True for the resistance route of table 5 – but the standard explicitly opens a second route for belts dissipating by corona.

    B · no

    "Only below 0.5 m/s"

    Speed limits apply to dissipative belts. They do not turn a non-dissipative belt into a permitted one.

    C · yes, with proof

    "Possibly – with an expert test"

    Belt type A stayed ≤ 20 nC at 10 µA and ≤ 27 nC at 20 µA on a grounded roller: below the IIB and IIA Zone 1 limits respectively – provided all rollers and drums are conductive and grounded.

    The final decision stays with the ignition hazard assessment of the actual conveyor: speed, climate, product, splices and maintenance of the earthing.
    The dynamic charge-dissipation method

    Strengths, limits – and what R&D can do with it

    Strengths

    • Represents continuous charging, like a running belt
    • Directly comparable to the nC limits of IEC TS 60079-32-1
    • Works for belts that dissipate by corona
    • Two current levels show the safety margin

    Limits

    • Laboratory sample, not a running conveyor
    • One roller diameter and contact area
    • One climate (23 °C / 20 %rh)
    • New belts – no ageing, wear, dirt or splices
    • Not an accredited, standardised method

    Use in R&D

    • Compare constructions and yarn layouts early
    • Test after abrasion and cleaning
    • Include the splice region
    • Check lower humidity and other roller diameters
    • Correlate with field measurements on a running belt (ISO 21179)
    Interactive · decision aid

    Which route for my belt?

    Surface resistance, both sides (strip electrodes)
    Layered belt: through-resistance
    Conductive yarns / corona dissipation
    Intended area
    Belt speed
    ?
    Quiz

    Your turn

    Same belt, same corona charging – but the stainless-steel return roller is no longer grounded. What maximum transferred charge did we measure?
    Click the answer of the group, then → to reveal.
    Summary

    Six things to remember

    1

    Separation at the drum is the charge source

    It grows with speed, tension, contact width and dry air.

    2

    Ground every roller and drum

    Isolated conductors give sparks – the most powerful discharge.

    3

    ESD ≠ ATEX

    Different goals, criteria and tests – specify both.

    4

    Two routes to Ex suitability

    Dissipative by resistance (table 5) – or proven by an expert chargeability test.

    5

    Measure while charging

    The dynamic method shows what a belt evacuates under continuous charging.

    6

    State the conditions

    Properties hold only with grounded pulleys, within a speed and climate range, over the belt's life.

    ?